Product Overview: Kaelus Bench Top PIM Analyzers IBA Series

Kaelus Bench Top PIM Analyzers IBA Series

The iBA Series PIM Analyzer is a complete bench top and rack mounting PIM test solution used with a system controller* and intuitive user software. This economical solution comes in model variations that cover all major commercial wireless bands. The iBA base model (A-Series) measures Reverse/reflected IM only. The B-Series adds a second test port to support a Reverse IM measurement on either port and a forward IM measurement port-to-port. Both the A & B Series can be fitted with optional internal DC/AISG Bias Tee.

FEATURES

  • Fully integrated system in compact size
  • Fully configurable frequencies, power and IM products
  • USB control interface
  • Frequency sweep and time trace modes
  • Range to Fault (RTF) optional accessory, allows users to measure distance to Return Loss and PIM Fault
  • Optional internal DC / AISG Bias-Tee
  • Compatible with ACE calibration tool
SYSTEM
Measurement method A-Series: Reverse (Reflected) PIM | B-Series: Port 1 Reverse; Port 2 Reverse; Port-to-Port Forward PIM
Residual PIM < -125dBm (x 2 @ 43dBm)
iBA-2600A & B < -125dBm / over 90% of the band (x 2 @ 43dBm)
IM order 3rd, 5th, 7th, 9th and 11th order
User interface ports 1 x USB Type B, 1 x USB Type A, 1x Monitor Port (N Female).
Bias-Tee Option: 1 x AISG / DC on 8 Pin DIN Female
Test ports A-Series: 1 x RF Output (7-16 DIN Female); B-Series: 2 x RF Output (7-16 DIN Female)
TRANSMITTER
Transmit frequencies Refer to iBA series model table
Frequency increment 100kHz
Frequency accuracy ± 5ppm maximum, aging ± 1ppm maximum after first year
Power per tone (adjustable) +20 to +44dBm | 0.1W to 25W (Effective June 28, 2018)
+30 to +44dBm | 1W to 25W (Units manufactured before June 28, 2018)
Power accuracy (per tone) ± 0.35dB
RECEIVER
Receive band (100kHz steps) Refer to iBA Series Model Table
Measurement noise floor < -130 dBm (-135 dBm, typical)
Measurement range -55dBm to -130dBm
AISG/DC OPTION
Factory Fitted AISG Modem and Bias Tee AISG ON/OFF keying AND/OR +28V DC available on the RF Test port (on Port 1 for the B Series iBA)
AISG baseband (RS485) AND/OR +28V DC is available on the 8 pin DIN Female connector
AISG/DC Specifications: (DC specs applies to both ports) Output Voltage: +28V max
Current: 2.5A max
Frequency: 2.076 to 2.276 MHz
Return loss: >10dB
Ordering Information Add Suffix -1 to model number
Eg iBA-1800A-1 or iBA-1800B-1 to include the AISG/DC Option
ELECTRICAL
Mains power 115 – 230V, 50 – 60Hz AC
Power consumption 800W
MECHANICAL
Dimensions H x D x W A series- 175.3 x 508 x 482.6mm | 6.9 x 20 x 19in
B series- 264.2 x 508 x 482.6mm | 10.4 x 20 x 19in
Weight A series- 22.7kg | 50lbs
B series- 30kg | 66lbs
Cooling Forced air (100mm gap to be maintained at the rear when rack mounted, 1U spacing recommended between units)
ENVIRONMENTAL
Temperature range +10ºC to +40ºC | +50°F to +104°F (operating)
Ingress protection Indoor use (or similar protected outdoor environment)
Operational humidity 5% to 90% non-condensing
Storage temperature range -20°C to +60°C | -4°F to +140°F
IBA A-SERIES MODELS
Reverse IM only
MODEL TX RANGE RX RANGE (PIM) IM ORDER RTF MODULE
iBA-0700LA 728-746MHz 698-716MHz 3rd, 5th, 7th, 9th, 11th RTF-1000
iBA-0700HA 728-757MHz 776-787MHz 3rd, 5th, 7th, 9th, 11th RTF-1000
iBA-0703A 758-803MHz 703-748MHz 3rd, 5th, 7th, 9th, 11th RTF-1000
iBA-0790A 791-821MHz 832-862MHz 3rd, 5th, 7th, 9th, 11th RTF-1000
iBA-0850A 869-894MHz 824-849MHz 3rd, 5th, 7th, 9th, 11th RTF-1000
iBA-0901A 925-960MHz 880-915MHz 3rd, 5th, 7th, 9th, 11th RTF-1000
iBA-1800A 1805-1880MHz 1710-1785MHz 3rd, 5th, 7th, 9th, 11th RTF-2000
iBA-1921A 1930-1990MHz / 2110-2155MHz 1710-1755MHz / 1850-1910MHz 3rd, 5th, 7th, 9th, 11th RTF-2000
iBA-2101A 2110-2170MHz 1920-2080MHz 3rd, 5th, 7th, 9th, 11th RTF-2000
iBA-2600A 2620-2690MHz 2500-2570MHz 3rd, 5th, 7th, 9th, 11th RTF-2600
IBA B-SERIES MODELS
Reverse IM on port 1 and port 2, Forward IM on port 1 to port 2
MODEL TX RANGE RX RANGE (PIM) IM ORDER RTF MODULE
iBA-0700LB 728-746MHz 698-716MHz 3rd, 5th, 7th, 9th, 11th RTF-1000
iBA-0700HB 728-757MHz 776-787MHz 3rd, 5th, 7th, 9th, 11th RTF-1000
iBA-0703B 758-803MHz 703-748MHz 3rd, 5th, 7th, 9th, 11th RTF-1000
iBA-0790B 791-821MHz 832-862MHz 3rd, 5th, 7th, 9th, 11th RTF-1000
iBA-0850B 869-894MHz 824-849MHz 3rd, 5th, 7th, 9th, 11th RTF-1000
iBA-0901B 925-960MHz 880-915MHz 3rd, 5th, 7th, 9th, 11th RTF-1000
iBA-1800B 1805-1880MHz 1710-1785MHz 3rd, 5th, 7th, 9th, 11th RTF-2000
iBA-1921B 1930-1990MHz / 2110-2155MHz 1710-1755MHz / 1850-1910MHz 3rd, 5th, 7th, 9th, 11th RTF-2000
iBA-2101B 2110-2170MHz 1920-2080MHz 3rd, 5th, 7th, 9th, 11th RTF-2000
iBA-2600B 2620-2690MHz 2500-2570MHz 3rd, 5th, 7th, 9th, 11th RTF-2600

 

Reviews

There are no reviews yet.

Be the first to review “Kaelus Bench Top PIM Analyzers IBA Series”

Your email address will not be published. Required fields are marked *


Kaelus Bench Top PIM Analyzers IBA Series Calibration

Request a Calibration Quote

Calibration, inspection, cleaning, and/or repair may be available for the Kaelus Bench Top PIM Analyzers IBA Series. Click to inquire about our calibration or other services.