Product Overview: Kaelus IQA-850B PIM Analyzer
Kaelus IQA-850B PIM Analyzer
The Kaelus IQA-850B PIM Analyzer operates at a transmission and receiving band frequency range of approximately 800-900MHz. The IQA Passive Intermodulation (PIM) analyzer is a feature-rich, high power PIM test solution which fulfills the IEC 62037 standard for passive intermodulation, its innovative design increasing safety and efficiency. This field-proven analyzer enables network operators to improve site performance by finding and eliminating sources of passive intermodulation at the cell site. The design includes an integrated panel PC with intuitive touch screen interface for performing tests and generating site reports. The Kaelus IQA-850B PIM Analyzer performs immediate and accurate Distance-to-PIM tests, informing you of the distance and magnitude of all PM sources simultaneously, both within the antenna system and beyond the antenna itself. With the growing amount of systems which utilize duplex transmissions paired with collocated transmitters and receivers, the Kaelus IQA-850B PIM Test Set is an essential tool to discover distortions to RF transmissions.
Frequency Ranges | |
---|---|
TX RANGE | 869-894MHz |
RX RANGE (PIM) | 824-849MHz |
System | |
Measurement method | Reverse (reflected) PIM, 3rd, 5th, 7th and 9th order |
Residual PIM | < -115dBm/-158dBc max (<-125dBm/-168dBc typ.) |
User interface ports | 2x USB, x1 LAN 1x RF output (7-16 DIN female) |
Display | 8.4in (213mm) touch screen display |
Transmitter | |
Frequency increment | 50 kHz |
Frequency accuracy | ± 5ppm (max), aging ± 1ppm (max) after first year |
Power per tone (adjustable) | 2x 2 to 20W (+33 to +43dBm) |
Power accuracy (per tone) | ± 0.5dB (max) |
Receiver | |
Measurement noise floor | < -128dBm |
Measurement range | -50dBm to -128dBm |
Electrical | |
Mains power | 115-230V, 50/60Hz AC |
Power consumption | 650W |
Mechanical | |
Dimensions | 19 x 18 x 12in (500 x 457 x 305mm) |
Weight | < 50lbs (22.7kg) |
Cooling | Forced air |
Environmental | |
Operating temperature range | -10°C to +40°C |
Storage temperature range | -20°C to +60°C |
Ingress protection (IP) | IP20 (with lid open) IP21 (with lid closed) |
Relative humidity | 5% to 95% RH non-condensing |
Mechanical shock | 40G shock rating |
Reviews