Product Overview: HVA45TD VLF/DC Hipot Tester with Integrated Tan Delta
Unmatched Efficiency:
-
Consolidated Testing: The HVA45TD integrates VLF, DC, and Tan Delta testing into a single unit, eliminating the need for separate equipment and streamlining workflows. This translates to faster testing times and reduced labor costs.
-
Exceptional Portability: The rugged IP67-rated case ensures the HVA45TD withstands harsh environments while maintaining exceptional portability. This minimizes downtime and allows for efficient field testing.
-
Universal Capabilities: With a high test capacity of 10uF, the HVA45TD tackles a wide range of loads and cables, maximizing its utility and reducing the need for specialized equipment.
Investment in Reliability:
-
Reduced Risk: The HVA45TD adheres to all relevant industry standards, including IEEE400, 400.2, IEC 60502, and CENELEC HD620/621, ensuring reliable and compliant testing results. This minimizes the risk of costly errors and project delays.
-
Ready to Deploy: The HVA45TD arrives pre-calibrated and includes all necessary accessories, including TD Control Center software for comprehensive data management. This eliminates upfront investment in additional equipment and ensures a smooth deployment process.
Elevate Your Testing Strategy:
The HVA45TD represents a strategic investment that delivers significant cost savings through increased efficiency, reduced downtime, and minimized risk.
Technical Data
Model | HVA45 TD | |
Input Supply Voltage | 100 – 240 V 50/60 Hz | |
Input Supply Power | 1.2kVA | |
Output Voltage (Max.) |
Sinewave | 0 – 45 kVpeak, 32 kVrms |
DC | ± 0-45 kV | |
Squarewave | 45 kV | |
Accuracy | ± 1%, Resolution: 0.1 kV, | |
Output Current | 0-60 mA, Accuracy: ± 1%, Resolution: 1 µA | |
Resistance Range | 0.1 MQ – 20 GQ | |
Output Frequency | 0.01-0.1 Hz in Steps of 0.01 Hz (default 0.1 Hz) Automatic Frequency Optimization | |
Output Load |
1 µF @ 0.1 Hz @ 32 kVrms
10.0 µF @ 0.01 Hz @ 32 kVrms 10.0 µF Maximum Capacitance* |
|
Sheath Test | Max Test Voltage: 10 kV | Trip Current: 0.1 mA – 5.0 mA | |
Sheath Fault Location | Max Test Voltage: 10 kV | Pulse/Period: 1:3 / 4 s, 1:5 / 4 s, 1:5 / 6 s, 1:9 / 6 s | |
Metering | Voltage and Current (True rms and / or Peak), Tan Delta Capacitance, Resistance, Time, Flashover Voltage | |
Tan Delta Measurement | Accuracy ± 1 x 10-4. Fully Compliant with IEEE400.2 | |
Duty Cycle | Continuous ! | |
Test Modes | Manual & Automatic | |
Output Modes | AC (VLF) Sinewave Symmetrical and Load-Independent Across Full Range, DC (Plus or Negative Polarity), Burn/Fault Condition or Fault Trip Mode, Jacket/Sheath Testing, Squarewave | |
Safety | 50 / 60 Hz – 12kV Feedback Protection / Dual Discharge System (internal) | |
Computer Interfaces | Bluetooth and USB | |
Record Storage | Built-in Memory: Up to 50 Reports, 50 Test Sequences USB Flash Drive: Unlimited | |
PC Software | “HVA Control Center” and “TD Control Center” Windows Compatible | |
Weight | 39 kg/ 86 lbs | |
Dimensions | 500 mm x 305 mm x 457 mm/ 19.7” x 12” x 18” | |
Environment |
Storage Temperature: -25°C to 70°C (-13°F to 158°F) Operating Temperature: -20°C to 55°C (-4°F to 131°F) Humidity: 5-70% Non-Condensing | |
Upgrades (Optional) | Partial Discharge Diagnostic System PD60/PDTD60 | |
Rugged Transport Case for HVA45/TD and All Accessories. Part # 745 005 |