Product Overview: Fluke 715 mA / mV / V Process Calibrator
The Fluke 715 Volt mA Calibrator delivers outstanding performance, durability, and reliability in a compact, lightweight tool. Offered in the rugged Fluke 80 Series DMM package, the calibrator measures loop current as well as voltage output. It sources voltage to 200 mV or 20 V, measures loop current (0-20 mA, 4-20 mA) signals with 0 .01 % accuracy and 1 µA resolution, and measures voltage output process signals from PLCs and transmitters. It can source or simulate 4-20 mA loop current and provides a 24 V loop supply with simultaneous current measurement.
The 715 is also extremely easy to use with a simple push button interface similar to the multifunction Fluke 750 Series Documenting Process Calibrators. It features the rugged construction that Fluke tools are known for and is EMI tolerant and dust and splash resistant. It also features a removable battery door for quick battery changes.
Fluke 715 Features:
- Measure loop current (0-24 mA, 4-20 mA) signals with bery high accuracy of 0.015% and 1 mA resolution
- Measure voltage output process signals from PLCs, transmitters
- Source or simulate 24 mA loop current
- Source voltage to 100 mV or 10 mV
- 24V loop supply with simultaneous current measurement
- Enhanced voltage and current measure and source accuracy
- Improved battery life
- 250 Ohm HART resistor with loop power
- Holster features test lead storage
- Compatible with toolpack magnetic hanging system
- Step and linear ramp output function
- Configurable zero and span settings
Specifications: Fluke 715 Volt/mA Loop Calibrator
Functional Specifications | ||
Measure / Source mV | Range | 0 to 200 mV |
Resolution | 0.01 mV | |
Accuracy | 0.015% + 2 counts | |
Measure / Source V | Range | 0 to 20 V |
Resolution | 0.001 V | |
Accuracy | 0.01% + 2 counts | |
Measure / Source/ Simulate mA (% of span) | Range | 0 to 24 mA (-25% to 125%) |
Resolution | 0.001 mA | |
Accuracy | 0.01% + 2 counts | |
Sink (simulate transmitter) display mA or % of span | ||
Specifications | ||
Loop power | Range | 24 V DC |
Accuracy | ±10% | |
Drive; 20 mA into 1000 Ω for battery > 6.8 V; 700 Ω for battery 5.8 to 6.8 V | ||
Display | Clear 5 digit LCD | |
Environmental Specifications | ||
Operating temperature | -10°C to 55°C | |
Storage temperature | -40°C to 60°C | |
Humidity (without condensation) | 95% (10°C to 30°C) | |
75% (30°C to 40°C) | ||
45% (40°C to 50°C) | ||
35% (50°C to 55°C) | ||
Operating altitude | 3,000 m max | |
Safety Specifications | ||
Safety | CSA C22.2 No. 1010.1:1992 | |
Mechanical and General Specifications | ||
Size (L x W x D) | 187 x 87 x 32 mm | |
(7.93 x 3.86 x 2.06 in) | ||
Weight | Approx. 330 g | |
(21 oz) | ||
Warranty | 3 years | |
Shock and vibration | Random, 2 G, 5-500 Hz | |
1 m drop test | ||
Battery type | Single 9 V battery ANSI/NEDA 1604A or IEC 6LR619V alkaline |