TEST EQUIPMENT
MADE EASY ™

Fluke 715 mA / mV / V Process Calibrator

Fluke 715 mA / mV / V Process Calibrator

View Quote List
QTY:
 
Manufacturer

RENT THIS ITEM

Daily, Weekly, and Monthly rates are available on select items.

Product Overview: Fluke 715 mA / mV / V Process Calibrator

The Fluke 715 Volt mA Calibrator delivers outstanding performance, durability, and reliability in a compact, lightweight tool. Offered in the rugged Fluke 80 Series DMM package, the calibrator measures loop current as well as voltage output. It sources voltage to 200 mV or 20 V, measures loop current (0-20 mA, 4-20 mA) signals with 0 .01 % accuracy and 1 µA resolution, and measures voltage output process signals from PLCs and transmitters. It can source or simulate 4-20 mA loop current and provides a 24 V loop supply with simultaneous current measurement.

The 715 is also extremely easy to use with a simple push button interface similar to the multifunction Fluke 750 Series Documenting Process Calibrators. It features the rugged construction that Fluke tools are known for and is EMI tolerant and dust and splash resistant. It also features a removable battery door for quick battery changes.

Fluke 715 Features:

  • Measure loop current (0-24 mA, 4-20 mA) signals with bery high accuracy of 0.015% and 1 mA resolution
  • Measure voltage output process signals from PLCs, transmitters
  • Source or simulate 24 mA loop current
  • Source voltage to 100 mV or 10 mV
  • 24V loop supply with simultaneous current measurement
  • Enhanced voltage and current measure and source accuracy
  • Improved battery life
  • 250 Ohm HART resistor with loop power
  • Holster features test lead storage
  • Compatible with toolpack magnetic hanging system
  • Step and linear ramp output function
  • Configurable zero and span settings

Specifications: Fluke 715 Volt/mA Loop Calibrator

Functional Specifications
Measure / Source mV Range 0 to 200 mV
Resolution 0.01 mV
Accuracy 0.015% + 2 counts
Measure / Source V Range 0 to 20 V
Resolution 0.001 V
Accuracy 0.01% + 2 counts
Measure / Source/ Simulate mA (% of span) Range 0 to 24 mA (-25% to 125%)
Resolution 0.001 mA
Accuracy 0.01% + 2 counts
Sink (simulate transmitter) display mA or % of span
Specifications
Loop power Range 24 V DC
Accuracy ±10%
Drive; 20 mA into 1000 Ω for battery > 6.8 V; 700 Ω for battery 5.8 to 6.8 V
Display Clear 5 digit LCD
Environmental Specifications
Operating temperature -10°C to 55°C
Storage temperature -40°C to 60°C
Humidity (without condensation) 95% (10°C to 30°C)
75% (30°C to 40°C)
45% (40°C to 50°C)
35% (50°C to 55°C)
Operating altitude 3,000 m max
Safety Specifications
Safety CSA C22.2 No. 1010.1:1992
Mechanical and General Specifications
Size (L x W x D) 187 x 87 x 32 mm
(7.93 x 3.86 x 2.06 in)
Weight Approx. 330 g
(21 oz)
Warranty 3 years
Shock and vibration Random, 2 G, 5-500 Hz
1 m drop test
Battery type Single 9 V battery ANSI/NEDA 1604A or IEC 6LR619V alkaline

See more Fluke products here.

Reviews

There are no reviews yet.

Be the first to review “Fluke 715 mA / mV / V Process Calibrator”

Your email address will not be published. Required fields are marked *


Rent the Fluke 715 mA / mV / V Process Calibrator

Request Rental Quote Above

JM Test Rental options can help you save capital, get the latest technology, and expand your capabilities. Daily, Weekly and Monthly rates are available on select items.