Product Overview: AEMC OX 9062 IV Hand-held Oscilloscope
AEMC OX 9062 IV Hand-held Oscilloscope
The AEMC OX 9062 IV Hand-held Oscilloscope is a rugged, ergonomic, self-contained, hand-held, two-channel oscilloscope with 60 MHz bandwidth, 2 channel DMM 8000 cts, FFT function and recording mode, and power measurement.
Large touch screen 7-inch color LCD display
Ideal for both laboratory and field use, the Model OX 9062 utilizes the patented system of plug-and-play accessories, individual isolation of each of the measurement channels, and a range of remote management capabilities. The Ethernet link and Wi-Fi lets you remotely control the oscilloscope without loading any software to your PC. Android App available to download from Google play store.
AEMC OX 9062 IV Hand-held Oscilloscope Standard Accessories include:
Includes carrying case with shoulder strap, set of (2) 5 ft color-coded leads, alligator clips and test probes (4 mm diameter), 10 ft USB cable, µSD memory card, 1-PROBIX Banana Plug (4 mm) Adapter, set of (5) stylus pens, LI-ION 5.8 A• h battery, PA40W-2 power adapter with 110 V power cord.

AEMC OX 9062 IV Hand-held Oscilloscope Specifications:
| CHANNELS | |
| Inputs / Bandwidth | 2 Isolated channels |
| Input Impedance | 1 MΩ ± 0.5 %, approx. 12 pF |
| INTERFACE | |
| Screen Specifications | Color 7 in WVGA TFT LCD touch screen, 800 x 480 pixels |
| Display Mode | Vectors with interpolation – 2500 real acquisition points on screen |
| Traces On Screen | 2 Traces + 2 References (split screen and full screen modes) |
| Front Panel Control | 32 keys |
| Screen Control | Touch screen – ANDROID type icons and graphical commands |
| VERTICAL | |
| Vertical Sensitivity | 16 ranges from 2.5 mV to 200 V div and up to 156 µV/div om vertical zoom mode (12-bit converter) Accuracy ±2 % |
| Max Input Voltage | 600 V CAT III (1000 V per Probix) from (50 to 400) Hz – Probix connectors |
| Vertical Zoom | One-click Winzoom system (direct graphical zoom onscreen) x 16 max |
| HORIZONTAL | |
| Time Base Speed | 35 ranges from 1 ns/div. Accuracy ± (50 ppm + 500 ps) Roll mode from 100 ms to 200 s/div |
| Horizontal Zoom | One click Winzoom system (direct graphical zoom onscreen) x 100 max |
| TRIGGER | |
| Mode | Auto, Triggered, One-shot, Auto-level 50 % on all channels |
| Type | Edge, Pulse width (16 ns – 20 s) Delay (48 ns – 20 s) Counting (3 to 16,384 events) Continuous adjustment of Trigger position |
| Coupling | AC, DC GND, HFR, LFR, noise – Level and Hold-Off adjustable from 64 ns to 15 s |
| Autoset | Complete < 5 s with recognition of channels – Frequency > 30 Hz |
| Cursors | Two or three cursors: V and T with auto measurement: T1, T2, Dt, 1/Dt, dBV, Ph |
| DIGITAL MEMORY | |
| Max. Sampling Rate | 2.5 GS/s in one-shot mode on each channel (100 GS/s max. in ETS mode) 12 bits resolution |
| Memory Depth | 100 kpts per channel and file viewer in the manager |
| Memory Capacity | Internal = 1 GB to store the files Tace, text, configuration, math functions, System memory: .pdf print files, .png image files + high-capacity removable microSD-Card: SD 2 GB, SDHC (4 to 32) GB and SDXC > 32 GB |
| GLITCH Mode | Duration ≥ 2 ns – 500,000 Min/Max pairs |
| Display Modes | Envelope, vector, accumulation -, averaging (factors 2 to 64) XY (vector) and Y(f) = FFT |
| OTHER FUNCTIONS | |
| FFT Analyzer & Math Functions | FFT (Lin or Log) with measurement cursors – Functions, +, – x, / and mathematical function editor |
| Automatic Measurement | Simultaneously with waveform, 20 automatic measurements per channel and on the 4 channels simultaneously with scroll |
| Multimeter Mode | 2 channels 8000 counts + Min/Max/Frequency/Relative TRMS Time stamp graphic recording in logger mode |
| AC, DC, AC+DC Voltages | 600 mV to 600 VRMS 800 mV to 800 VDC Accuracy: 0.5 % Bandwidth 200 kHz |
| Power and PF | Active, Reactive, and Apparent power values plus Power Factor simultaneously with the U & I measurements |
| Resistance, Temperature, Capacitance, Frequency, and Diode Test on channel 1 only | |
| Acquisition | Duration: 20,000 s Interval: 0.2 s Files: 100,000 measurements |
| Harmonic Analyzer Mode | |
| Multi-Channel Analysis | (2) 61 orders, fundamental from (40 to 450) Hz in auto or manual mode |
| Simultaneous measurement | Total Vrms, THD and selected order (% fundamental, phase, frequency, Vrms) |
| GENERAL FEATURES | |
| Interface | Isolated USB, WiFi, and Ethernet, SD micro card for direct transfer to PC. Web server/client with cursor and automatic measurements |
| Batteries | Rechargeable LI-ION 5.8 A•h battery, External charger |
| Charging Time | (98 to 264) VAC (50/60 Hz) 2 hours when OFF |
| Battery life | Approx. 8 hours |
| Dimensions (L x W x H) | (11.5 x 8.29 x 2.6) in (292.5 x 210.6 x 66.2) mm |
| Weight | 4.7 lbs. (2.1 kg) |
| Altitude Operating | 2000 m (6560 ft) |
| Operating Temperature | (32 to 104) °F (0 to 40) °C ≤80 % RH |
| Storage Temperature | (-4 to 140) °F (-20 to 60) °C |
| IP Rating | IP54 per IEC 60529 |
| Safety | IEC/EN 61010-2-30 (1000 V CAT II; 600 V CAT III), IEC 1326-1 |










Reviews