Product Overview: AEMC OX 9102 IV Hand-held Oscilloscope
The Model OX 9102 Oscilloscope is a rugged, handheld device with a 100MHz bandwidth, two channels, a 2-channel DMM with 8000 counts, FFT function, recording mode, and power measurement. It features a large 7″ color LCD touch screen display. Ideal for both lab and field use, it has “plug-and-play” accessory support and remote control capabilities via Ethernet or Wi-Fi. An Android App is available for download from the Google Play Store.
CHANNELS | |
Inputs / Bandwidth | 2 Isolated channels |
Input Impedance | 1MΩ ± 0.5%, approx. 12pF |
INTERFACE | |
Screen Specifications | Color 7″ WVGA TFT LCD touch screen, 800 x 480 |
Display Mode | Vectors with interpolation – 2500 real acquisition points on screen |
Traces On Screen | 2 Traces + 2 References (split screen and full screen modes) |
Front Panel Control | 32 keys |
Screen Control | Touch screen – ANDROID type icons and graphical commands |
VERTICAL | |
Vertical Sensitivity | 16 ranges from 2.5mV – 200V/div and up to 156µV/div om vertical zoom mode (12-bit converter) – Accuracy ±2% |
Max Input Voltage | 600V/CAT III (1000V per Probix) – from 50 to 400 Hz – Probix connectors |
Vertical Zoom | “One click Winzoom” system (direct graphical zoom onscreen) x 16 max |
HORIZONTAL | |
Time Base Speed | 35 ranges from 1ns/div. – accuracy ±[50 ppm + 500 ps] – Roll mode from 100 ms to 200 s/div |
Horizontal Zoom | “One click Winzoom” system (direct graphical zoom onscreen) x 100 max |
TRIGGER | |
Mode | Auto, Triggered, One-shot, Auto-level 50% on all channels |
Type | Edge, Pulse width (16ns – 20s), delay (48ns – 20s), counting (3 to 16,384 events) Continuous adjustment of Trigger position |
Coupling | AC, DC GND, HFR, LFR, noise – Level and Hold-Off adjustable from 64ns to 15s |
Autoset | Complete <5s with recognition of channels – Frequency >30Hz |
Cursors | Two or three cursors: V and T with auto measurement: T1, T2, Dt, 1/Dt, dBV, Ph |
DIGITAL MEMORY | |
Max. Sampling Rate | 2.5GS/s in one-shot mode on each channel (100GS/s max. in ETS mode) 12 bits resolution |
Memory Depth | 100kpts per channel and file viewer in the manager |
Memory Capacity | Internal = 1GB to store the files: trace, text, configuration, math functions, System memory: .pdf print files, .png image files + high-capacity removable microSD-Card: SD 2GB, SDHC 4-32GB and SDXC >32GB |
GLITCH Mode | Duration ≥ 2ns – 500,000 Min/Max pairs |
Display Modes | Envelope, vector, accumulation -, averaging (factors 2 to 64) – XY (vector) and Y(f)=FFT |
OTHER FUNCTIONS | |
FFT Analyzer & Math Functions | FFT (Lin or Log) with measurement cursors – Functions, +, – x, / and mathematical function editor |
Automatic Measurement | Simultaneously with waveform, 20 automatic measurements per channel and on the 4 channels simultaneously with scroll |
Multimeter Mode | 2 channels, 8000 counts + Min/Max/Frequency/relative – TRMS – Time stamp graphic recording in logger mode |
AC, DC, AC+DC Voltages | 600mV to 600VRMS, 800mV to 800VDC: accuracy 0.5% Bandwidth 200kHz |
Power and PF | Active, Reactive, and Apparent power values plus Power Factor simultaneously with the U & I measurements |
Resistance, Temperature, Capacitance, Frequency, and Diode Test on channel 1 only | |
Acquisition | Duration: 20,000s – Interval: 0.2s – Files: 100,000 measurements |
Harmonic Analyzer Mode | |
Multi-Channel Analysis | 2, 61 orders, fundamental from 40 to 450Hz in auto or manual mode |
Simultaneous measurement | Total Vrms, THD and selected order (% fundamental, phase, frequency, Vrms) |
GENERAL FEATURES | |
Interface | Isolated USB, WiFi, and Ethernet, SD micro card for direct transfer to PC. Web server/client with cursor and automatic measurements |
Batteries | Rechargeable Li-Ion 6,900mAh 40W battery pack, External charger |
Charging Time | 98 to 264VAC (50/60Hz) 2 hours when OFF |
Battery life | Approx. 8 hours |
Dimensions (L x W x H) | 11.5 x 8.29 x 2.6” (292.5 x 210.6 x 66.2mm) |
Weight | 4.7 lbs. (2.1kg) |
Altitude Operating | 2000m (6560ft) |
Operating Temperature | 32° to 104°F (0 to 40°C) ≤80% RH |
Storage Temperature | -4° to 140°F (-20 to 60°C) |
IP Rating | IP54 per IEC 60529 |
Safety | IEC/EN 61010-2-30 (1000V CAT II; 600V CAT III), IEC 1326-1 |
Reviews