TEST EQUIPMENT
MADE EASY ™

Fluke Norma 6000 Series Portable Power Analyzers

To be quoted

Fluke Norma 6000 Series Portable Power Analyzers

View Quote List
QTY:
 
Category:

Product Overview: Fluke Norma 6000 Series Portable Power Analyzers

Fluke Norma 6000 Series Portable Power Analyzers

The Fluke Norma 6000 Series Portable Wideband Precision Power Analyzers offer unprecedented flexibility for conducting highly accurate power measurements, whether in a laboratory setting or out in the field. Engineered for portability, these lightweight, battery-powered analyzers eliminate the requirement to transport bulky, delicate, costly equipment into the field, enabling measurements to be taken directly at the load in virtually any environment. This direct measurement approach allows for a comprehensive understanding of equipment performance under real-world conditions, with actual variables, rather than solely within the confines of a test bench or laboratory environment.

Inputs Norma 6003 3 Voltage + 3 Current
Norma 6003+ 3 Voltage + 3 Current + 1 Motor
Norma 6004 4 Voltage + 4 Current
Norma 6004+ 4 Voltage + 4 Current + 1 Motor
Sample rate 200ks/s
Measurement update rate 100ms, 200ms, 500ms, 1s
Dimensions (H * W * L) 298mm x 215m x 96mm
Weight 3.5 kg (7.7 lbs)
Display 5.7 inch, TFT LCD, 640×480
Operating temperature -10 °C to +50 °C
Storage temperature -30 °C to +60 °C
Operating humidity Non-condensing (< 10 °C )
≤ 90 % RH (at 10 °C to 30 °C)
≤ 75 % RH (at 30 °C to 40 °C)
≤ 45 % RH (at 40 °C to 50 °C)
Operating altitude 2000m
Storage altitude 12000m
Ingress protection IP 50 (Terminals mated) according to IEC 60529:
Battery BP 291, 10.8V/5000mAh, 54Wh IEC 62133, UN38.3
Operating time: 10 Hours (on battery)
Safety IEC 61010-1: Pollution Degree 2
IEC 61010-2-030: CAT IV 600V, CAT III 1000 V
EMC IEC 61326-1: Industrial
IEC 61326-2-2
Warranty 1 Year
Communication Interface USB/RS485
Dual Analyzer Synchronization Mode Able to extend to 6, 7 or 8 channels (using multiple instruments)
PC Software Fluke Power Analyzer software
Storage Capacity 32GB
Data trend storage rate As per display rate
Main Function Meter, Scope, Harmonic, Phasor, Trend
Measuring Parameters RMS, DC Component, AC Component, Rectified Mean, Peak Value, Peak-Peak, Crest Factor, Form Factor, Fundamental Component, Fundamental Content, Harmonic Distortion, Harmonic Content, Harmonic Factor for voltages and currents, Active Power, Reactive Power, Apparent Power, Power Factor, Phase Shift, Efficiency, Impedance, Electric Energy, Charge/Discharge capacity (Ah), Frequency, Motor Speed, Torque, Mechanical Power, Mechanical Energy, Summation function
Electrical Specifications
Voltage
Range 10 V, 100 V, 1000 V
Crest Factor CF ≤ 2
Maximum Voltage 10 % overload
Input Impedance 2M Ω/10pF (Typical)
Temperature Coefficient 0.05 * (Spec)/k
Bandwidth 1000V range: 500kHz; 100V range: 200 kHz; 10V range:100 kHz
CMRR 120 dB @ 50/60 Hz
Accuracy (% reading + % range)
Range 1000 V 100 V 10 V
DC 0.1 + 0.1 0.1 + 0.1 0.1 + 0.2
AC (10Hz to 1kHz) 0.1 + 0.1 0.1 + 0.1 0.1 + 0.2
AC (10kHz) 5 + 0.5 5 + 0.5 5 + 0.5
Current
Crest Factor CF ≤ 2
Temperature Coefficient 0.05 x (Spec)/k
Overload capacity 10 % overload
CMRR 120 dB @ 50/60 Hz
Shunt (current input)
Measuring Range 0.1 A, 1 A, 10 A
Input Impedance 0.025 Ω (Typical)
Bandwidth 10 A range: 500 kHz; 1 A range: 200 kHz; 0.1 A range: 100 kHz
BNC (voltage input)
Range 0.1 V, 1 V, 10 V
Input Impedance 100k Ω/100pF (Typical)
Bandwidth 10 V range: 500 kHz; 1 V range: 200 kHz; 0.1 V range: 100 kHz
Accuracy (% reading + % range)
Range 10 A 1 A 0.1 A 10 V 1 V 0.1 V
DC 0.1 + 0.2 0.1 + 0.5 0.1+2 0.1+0.1 0.1+0.2 0.1+1
AC (10Hz to 1kHz) 0.1+0.1 0.1+0.2 0.1+1 0.1+0.1 0.1+0.1 0.1+0.5
AC (10kHz) 5+1 5+1 5+1 5+1 5+1 5+1
Motor Module (Torque and Speed)
Voltage Range ± 10 V dc, 10 % overload
Voltage Channels 2
Input Impedance 1.1M Ω (Typical)
Accuracy at dc 0.1 % range + 0.1 % reading
Pulse Channels 3
Pulse Logic High Threshold 2 V (Typical)
Pulse Logic Low Threshold 0.8 V (Typical)
Maximum Pulse Frequency 100 kHz
Motor Module (Torque and Speed)
Frequency Accuracy 0.05 % range + 0.05 % reading
Harmonics 100 (50Hz/60Hz)
Calculation method FFT/Interpolation

Reviews

There are no reviews yet.

Be the first to review “Fluke Norma 6000 Series Portable Power Analyzers”

Your email address will not be published. Required fields are marked *