TEST EQUIPMENT
MADE EASY ™

Fluke ii910 Acoustic Imaging Camera

Scan insulators, transformers, switch gears, and high voltage power lines with confidence with the Fluke ii910 Precision Acoustic Imager.

  • Partial discharge detection and PD testing
  • Finding and fixing PD to save on energy and cut costs
  • Capture and analyze partial discharge
  • One button capture
  • 7” display touchscreen
View Quote List
QTY:
 
Manufacturer

RENT THIS ITEM

Daily, Weekly, and Monthly rates are available on select items.

Product Overview: Fluke ii910 Acoustic Imaging Camera

Fluke ii910 Precision Acoustic Imager

Features:

  • Partial discharge detection and PD testing
  • Finding and fixing PD to save on energy and cut costs
  • Capture and analyze partial discharge
  • One button capture
  • 7” display touchscreen

Includes:

  • Imager
  • AC power supply and battery pack charger (including universal AC adapters)
  • Two rugged lithium ion smart battery packs
  • USB cable
  • Carrying case
  • Adjustable hand strap and neck strap

The ii910 Precision Acoustic Imager, engineered to locate partial discharge, corona discharge and gas and vacuum leaks.

This tool is suitable for teams who inspect and maintain power distribution and industrial high voltage equipment.

Partial discharge is a serious issue that teams monitor everyday. Whether you are scanning insulators, transformers, switch gears or high voltage powerlines you need to be sure that you spot a problem quickly and early. Partial discharge that goes unchecked can cause blackouts, fires, explosions, or death from arc flashes. In addition to the danger that this can pose to the environment and human lives, it also has a very steep price tag. Having equipment go down can cost millions of dollars per hour and studies have shown that a single data center outage could cost as much as $8,851 per minute. On top of this, the Department of Energy estimated that outages cost the US economy $150 billion annually.

Areas to assess for partial discharge:

  • Insulators
  • Transformers
  • High voltage powerlines
  • Switch gears
  • Arrestors
  • Busbars
  • High voltage coils
  • Breakers
  • Capacitors

Perfect tool for:

High voltage electricians

Electrical test engineers

Grid maintenance teams

Specifications: Fluke ii910 Precision Acoustic Imager

Sensors
Frequency band 2 kHz to 100 kHz
Detection range 0.5 to > 120 meters (1.6 to > 393 feet)*
Field of View 63 ° ± 5 °
Nominal frame rate 25 FPS
*Depending on ambient conditions
Built-in digital camera (visible light)
Field of View (FOV) 63 ° ± 5 °
Focus Fixed lens
Display
Size 7″ LCD with backlight, under-sunlight readable
Resolution 1280 x 800 (1,024,000 pixels)
Touchscreen Capacitive
Acoustic image Yes, SoundMap™ image
Image storage
Storage capacity Internal memory with the capacity for 999 picture files and 20 video files
Image format Blended visual and SoundMap™.JPG or .PNG
Video format Blended visual and SoundMap™.MP4
Video length 5 minutes maximum
Digital export USB-C for data transfer
Acoustic Measurements
Measurement range 12.1 dB SPL to 114.6 dB SPL ±1 dB SPL 2 kHz
4.4 dB SPL to 101.2 dB SPL ±2 dB SPL 19 kHz
12.8 dB SPL to 119.2 dB SPL ±1 dB SPL 35 kHz
19.8 dB SPL to 116.1 dB SPL ±3 dB SPL 52 kHz
41.4 dB SPL to 129.0 dB SPL ±1 dB SPL 80 kHz
54.4 dB SPL to 135.5 dB SPL ±1 dB SPL 100 kHz
Auto max/min dB gain Auto or manual, user selectable
Frequency band selection User selectable through user-made presets or manual entry
Software
Ease of use Intuitive user interface
Trend graphs Frequency and dB scale
Spot markers dB level reading at center point of the image
Battery
Batteries (field-replaceable, rechargeable) 2 x Rechargeable Li-ion, Fluke BP291
Battery life 6 hours/battery (product includes spare battery)
Battery charging time 3 hours
Battery charging system External dual-bay charger, EDBC 290
General Specifications
Standard palettes 3: Grayscale, Ironbow, Blue-Red
Operating temperature 0 °C to 40 °C (32 °F to 104 °F)
Storage temperature -20 °C to 70 °C (-4 °F to 158 °F) Without batteries
Relative humidity 10 % to 95 % non-condensing
Size (H x W x L) 186 x 322  x 68 mm (7.3 x 12.7 x 2.7 inches)
Weight (battery included) 1.7 kg (3.75 pounds)
Ingress Protection (IP) IP40 protection against particles 1mm or greater and dripping water
Warranty 2 year
Self-diagnostic notification Array-health test to identify when microphone array needs attention
Supported languages Dutch, English, Finish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese
RoHS compliant Yes
Safety
General safety IEC 61010-1
Electromagnetic Compatibility (EMC) International IEC 61326-1: Portable Electromagnetic Environment IEC 61326-2-2
CISPR 11: Group 1, Class A
Korea (KCC) Class A Equipment (Industrial Broadcasting & Communication)
USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.