Fluke Calibration / Hart Scientific 1586A

Super-DAQ Precision Temperature Scanner

View Quote List
QTY:
 
Manufacturer

SKU: 1586A Category:

Product Overview: Fluke Calibration / Hart Scientific 1586A

Fluke Calibration / Hart Scientific 1586A

The 1586A Super‑DAQ is the most accurate and flexible temperature data acquisition system on the market. It scans and records temperature, dc voltage, dc current, and resistance for up to 40 input channels and scan speeds as fast as 10 channels per second. The Super-DAQ can be configured for use as a multi-channel data logger in the factory or as a precision reference thermometer for benchtop sensor calibration in the lab.

  • Measure thermocouples, PRTs, thermistors, dc voltage, dc current, and resistance
  • Best-in-class temperature measurement accuracy
    • PRTs ± 0.005 °C (using external DAQ‑STAQ Multiplexer)
    • Thermocouples: ± 0.5 °C (using High-Capacity Module and internal CJC)
    • Thermistors: ± 0.002 °C
  • Input channels: Up to 40 isolated universal inputs
  • Flexible configuration: Internal High-Capacity Module and/or DAQ-STAQ Multiplexer
  • Selectable scan speed: Up to 10 channels per second
  • Four modes of operation: Scan, Monitor, Measure, Digital Multimeter (DMM)
  • Real-time color trending: Chart up to four channels simultaneously
  • 6 1/2 digit display resolution for dc voltage, dc current, and resistance
  • Current reversal minimizes thermoelectric effects, improving PRT/RTD measurment accuracy
  • Automated sensor calibration: Control Fluke Calibration temperature sources such as dry-wells or micro-baths for automated calibration routines
  • Data storage: Records up to 20 MB of data and setup files to internal non-volatile memory or to an external USB drive. Transfer data to a PC using the USB drive or LAN connection and view data in Microsoft® Excel
  • Data security: Administrator and user profiles for protecting settings and ensuring test traceability
  • Mx + B scaling and channel offset zero function
  • Alarms: Two independent, user-defined alarms for each channel indicate when an upper or lower range has been exceeded

Fluke Calibration / Hart Scientific 1586A

General Specifications
Mains Voltage 100 V Setting: 90 V to 110 V

120 V Setting: 108 V to 132 V

220 V Setting: 198 V to 242 V

240 V Setting: 216 V to 264 V

Frequency 47 Hz to 440 Hz
Power Consumption  36 VA peak (24 W average)
Environment Temperature Operating: 0 °C to 50 °C

Full accuracy: 18 °C to 28 °C

Storage: −20 °C to 70 °C

Warm-up: 1 hour to full accuracy specifications

Relative Humidity (non-condensing) Operating:  0 °C to 30 °C <80 %;

30 °C to 50 °C <50 %

Storage: −20 °C to 70 °C <95 %

Altitude Operating: 2,000 m

Storage: 12,000 m

Vibration and Shock  Complies with MIL-PRF-28800F Class 3
Channel Capacity Total analog channels: 45

Voltage/resistance channels: 41

Current channels:  5

Digital I/O: 8 bits

Totalizer: 1

Alarm outputs: 6

Trigger input: 1

Input Protection  50 V all functions, terminals and ranges
Math Channels Number of channels: 20

Operations: sum, difference, multiply, divide, polynomial, power, square root, reciprocal, exponential, logarithm, absolute value, average, maximum, minimum

Triggers interval, external (trigger input), alarm, remote (bus), manual, automated test
Memory Scan data RAM: 75,000 readings with timestamp

Data/Setup flash memory: 20 MB

USB Host Port Connector type: Type A

Function: Memory

File system: FAT32

Memory capacity: 32 GB

USB Device Port Connector type: Type B

Class: Instrument

Function: Control and data transfer

Command protocol: SCPI

LAN Function: Control and data transfer

Network protocols: Ethernet 10/100, TCP/IP

Command protocol: SCPI

RS-232 Connector: D-sub 9 pin (DE-9)

Baud rates: 1200, 2400, 4800, 9600, 19200, 38400

Function: Temperature source control output

Dimensions Height: 150 mm

Width: 245 mm

Depth: 385 mm Weight: 6 kg (typical configuration)

Shipping Weight: 9.5 kg (typical configuration)

Conformity CE, CSA, IEC 61010 3rd ed.

 

Measurement Specifications
Accuracy specifications generally apply with medium and slow sample rates (unless otherwise noted), after a warm-up time of 1 hour, and within an environment temperature range of 18 °C to 28 °C, and may depend on the channel. The confidence level for accuracy specifications is 95 % within 1 year of calibration.
Scan rate Fast: 10 channels per second max (0.1 seconds per channel) Medium: 1 channel per second (1 second per channel)

Slow: 4 seconds per channel

Display Resolution 6 1/2 digits (see Measurement Characteristics tables below to find the display resolution of temperature readings)

 

PRT/RTD
Temperature Range −200 °C to 1200 °C (depending on the sensor)
Resistance Range 0 Ω to 4 kΩ
Offset Compensation 0 Ω to 400 Ω, 4-wire: automatic current reversal

400 Ω to 4000 Ω or 3-wire: none

Source Current Reversal Interval (0 Ω  to 400 Ω range)  Fast sample rate: 2 ms

Medium sample rate: 250 ms

Slow sample rate: 250 ms

Maximum Lead Resistance (4-wire Ω)  2.5 % of range per lead for 400 Ω and 4 kΩ ranges
PRT/RTD Resistance Accuracy
Accuracy is given as % of measurement or ohms, whichever is greater. Basic accuracy is for 4-wire PRT/RTD. When using 3-wire PRT/RTD add 0.013 Ω to the accuracy specification for internal resistance mismatch and voltage offset if using Channel 1, or add 0.05 Ω if using channels x01 through x20. If the environment temperature is outside the specified range, multiply the temperature coefficient numbers by the temperature deviation and add to the accuracy specification.

See more Thermometers here. 