Product Overview: Fluke 1577 1000v Insulation Multimeter
Fluke 1577 1000v Insulation Multimeter
Two powerful tools in one
The Fluke 1587 and 1577 Insulation Multimeters combine a digital insulation tester with a full-featured, true RMS digital multimeter in a single, compact, handheld unit, which provides maximum versatility for both troubleshooting and preventative maintenance.
Whether you work on motors, generators, cables, or switch gear, the Fluke 1587/1577 Insulation Multimeters are ideally suited to help you with your tasks and at a cost that is far less than buying the two products.
Fluke 1577 1000v Insulation Multimeter Includes:
- Remote probe
- Test leads
- Alligator clips
- Hard case
- Four AA alkaline batteries
- Quick Reference Guide
- CD Rom with Manual
|
Specifications |
Voltage DC |
Maximum Voltage: |
1000 V |
Accuracy: |
1577: ±(0.2%+2) |
|
1587: ±(0.09%+2) |
Maximum Resolution: |
0.001V |
|
Voltage AC |
Maximum Voltage: |
1000 V |
Accuracy: |
1577: ±(2%+3) |
|
1587: ±(2%+3) |
AC Bandwidth: |
1587: 5kHz* |
|
*with low pass filter; 3db @ 800 Hz |
Maximum Resolution: |
0.1 mV |
|
Current DC |
Maximum Amps: |
400mA |
Amps Accuracy: |
1577: ±(1.0%+2) |
|
1587: ±(0.2%+2) |
Maximum Resolution: |
0.01 mA |
|
Current AC |
Maximum Amps: |
400mA |
Amps Accuracy: |
1577: ±(2.0%+2)* |
|
1587: ±(1.5%+2)* |
|
* 1kHz bandwidth |
Maximum Resolution: |
0.01 mA |
|
Resistance |
Maximum Resistance: |
50 MΩ |
Accuracy: |
1577: ±(1.2%+2) |
|
1587: ±(0.9%+2) |
Maximum Resolution: |
0.1Ω |
|
Capacitance(1587 only) |
Maximum Capacitance: |
9,999 µF |
Accuracy: |
±(1.2%+2) |
Maximum Resolution: |
1 nF |
|
Frequency (1587 only) |
Maximum Frequency: |
100 kHz |
Accuracy: |
±(0.1%+1) |
Maximum Resolution: |
0.01 Hz |
|
Temperature Measurement (1587 only) |
|
-40.0 °C to 537 °C |
|
-40.0 °F to 998 °F |
|
excluding probe |
|
Diode Test (1587 only) |
Range: |
6 V |
Resolution: |
1 mV |
Accuracy: |
±(2 % + 1) |
|
Insulation Test |
Minimum Test Current @ 1kΩ/V: |
|
Test Voltages: |
1577: |
500, 1000 V |
1587: |
50, 100, 250, 500, 1000 V |
|
Maximum Resistance per Test Voltage: |
50V: |
|
100V: |
|
250V: |
|
500V: |
|
1000V: |
1577: 600 MΩ |
|
1587: 2 GΩ |
|
Maximum Resolution per Test Voltage: |
50V: |
0.01 MΩ |
100V: |
0.01 MΩ |
250V: |
0.1 MΩ |
500V: |
0.1 MΩ |
1000V: |
0.1 MΩ |
|
Accuracy per Test Voltage: |
50V: |
±(3 % + 5) |
100V: |
±(3 % + 5) |
250V: |
±(1.5 % + 5) |
500V: |
1577: ±(2.0 % + 5) |
|
1587: ±(1.5 % + 5) |
1000V: |
1577: ±(2.0 % + 5) |
|
1587: ±(1.5 % + 5) to 600 MΩ, ±(10 % + 3) above 600 MΩ |
|
Environmental Specifications |
Operating temperature |
|
Storage temperature |
|
Humidity (Without Condensation) |
|
0% – 95% (10 °C – 30 °C) |
|
0% – 75% (30 °C – 40 °C) |
|
0% – 40% (40 °C – 55 °C) |
|
Operating Altitude |
|
Safety Specifications |
Overvoltage category |
|
Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement CAT III 1000 V and CAT IV 600 V |
|
Agency Approvals |
|
2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III 600 V |
|
Mechanical & General Specifications |
Size |
|
203 x 100 x 50 mm (with holster) |
|
Weight |
|
Warranty |
|
Battery life Alkaline |
Meter use: |
1000 hours |
Insulation test use: |
Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off. |
|
IP Rating |
|
See more 1000V Megohmmeters here.