Product Overview: Ametek CTC-660 28 to 660°C (82 to 1220°F) Dry-Block Calibrator
Ametek CTC-660 28 to 660°C (82 to 1220°F) Dry-Block Calibrator
Ametek CTC-660 Features:
• Temperature range from -25 to 1200°C
• Crisp, full-color display, with improved navigation
• Auto step function with up to 12 preset temperature points
• Optimized switch test with automatic up and down test runs
• Manual calibration using pre-defined temperature points
• Memory to store up to 5 calibration processes
• Optional input for reference temperature sensor, to increase the accuracy even more
Each Unit Includes
- CTC dry-block calibrator (user specified)
- Mains power cable (user specified)
- Traceable certificate – temperature performance
- Tool for insertion tubes
- User manual
- Test cables (1 x red, 1 x black)
- USB cable
- JofraCal calibration software
- CTC-660 includes a Heat Shield
Temperature
Temperature Range
Range. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 to 660°C / 82 to 1220°F
Lowest calibration temperature. . . . . . . . . . ambient +5°C / 41°F
Accuracy
CTC-660 with internal ref. sensor. . . . . . . . . . . . . ±0.85°C /±1.53°F
CTC-660 with STS-120. . . . . . . . . . . . . . . . . . . . . . . . ±0.45°C /±0.81°F
Stability
CTC-660. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .±0.08°C / ±0.14°F
Measured after the stability indicator has been on for 10 minutes.
Measuring time is 30 minutes.
Radial Homogeneity (difference between holes)
CTC-660. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.1°C / 0.18°F
Settings
Resolution. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 or 0.1 or 0.01
Units. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .°C or °F or K
Heating Time
CTC-660. . . . . . . . . . . .23 to 660°C / 73 to 1220°F. . . 18 minutes
All specifications are given with an ambient temperature 23° C/73.4° F
± 3° C/5.9° F. Specified at 115 V/230 V.
Cooling Time
CTC-660. . . . . . . . . 660 to 100°C / 1220 to 212°F. . . 39 minutes
CTC-660. . . . . . . . . . . .100 to 50°C / 212 to 122°F. . . 18 minutes
Time to Stability (typical)
CTC-660. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 minutes
Mains Power
Voltage. . . . . . . . . . . . . . . . . . . . . .115 V (90-127) / 230 V (180-254)
Max Power Consumption. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1150 VA
Frequency, US deliveries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Hz ±3
Frequency, non US deliveries. . . . . . . . . . . . . . . 50 Hz ±3, 60 Hz ±3
Physical Specifications
Dimension L x W x H. . .248x148x305 mm / 9.76×5.83×12.01 in
Weight
CTC-660. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6.1 kg / 13.4 lb
Immersion Depth
CTC-660. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115 mm / 4.53 in
Well diameter
CTC-660. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 mm / 1.02 in
Insert Dimensions (diameter x length)
CTC-660. . . . . . . . . . . . . . . . . . 25,7 mm x 120 mm / 1.01 x 4.72 in
Electrical
Switch Input (dry contact)
Test Voltage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Maximum 14 VDC
Test Current. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maximum 1 mA
Digital Interface
USB 2.0
Environmental
Operating Temperature
0 to 50°C / 32 to 122°F
Storage Temperature
-20 to 50°C / -4 to 122°F
Humidity
5 to 90% Rh, non-condensing
Protection Class
IP-10
External reference sensor
STS-120-A-966. . . . . . . . . . . . . . . . . . . . . . .0 to 660°C / 32 to 1220°F
Accuracy
Hysteresis (@ 0°C / 32°F) . . . . . . . . . . . . . . . . . . . . . . 0.01°C / 0.018°F
Long Term Stability (@ 0°C / 32°F). . . . . . . . . . . . 0.014°C / 0.025°F
Repeatability. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.004°C/ 0.007°F
Sensing element
Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pt100
Response time
STS-120-A: t0.5 (50%) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 sec.
STS-120-A: t0.9 (90%) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 sec.
Dimensions
Diameter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 mm / 0.157 in
Length. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151 mm / 5.95 in
Max. height over calibrator top. . . . . . . . . . . . . . . . .25 mm / 0.94 in
See more Dry Block/ Liquid here.
Reviews
There are no reviews yet.