Product Overview: Ametek CTC-660 28 to 660°C (82 to 1220°F) Dry-Block Calibrator

Ametek CTC-660 28 to 660°C (82 to 1220°F) Dry-Block Calibrator

Ametek CTC-660 Features:

• Temperature range from -25 to 1200°C
• Crisp, full-color display, with improved navigation
• Auto step function with up to 12 preset temperature points
• Optimized switch test with automatic up and down test runs
• Manual calibration using pre-defined temperature points
• Memory to store up to 5 calibration processes
• Optional input for reference temperature sensor, to increase the accuracy even more

Each Unit Includes

  • CTC dry-block calibrator (user specified)
  • Mains power cable (user specified)
  • Traceable certificate – temperature performance
  • Tool for insertion tubes
  • User manual
  • Test cables (1 x red, 1 x black)
  • USB cable
  • JofraCal calibration software
  • CTC-660 includes a Heat Shield

Temperature
Temperature Range
Range. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 to 660°C / 82 to 1220°F
Lowest calibration temperature. . . . . . . . . . ambient +5°C / 41°F
Accuracy
CTC-660 with internal ref. sensor. . . . . . . . . . . . . ±0.85°C /±1.53°F
CTC-660 with STS-120. . . . . . . . . . . . . . . . . . . . . . . . ±0.45°C /±0.81°F
Stability
CTC-660. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .±0.08°C / ±0.14°F
Measured after the stability indicator has been on for 10 minutes.
Measuring time is 30 minutes.
Radial Homogeneity (difference between holes)
CTC-660. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.1°C / 0.18°F
Settings
Resolution. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 or 0.1 or 0.01
Units. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .°C or °F or K
Heating Time
CTC-660. . . . . . . . . . . .23 to 660°C / 73 to 1220°F. . . 18 minutes
All specifications are given with an ambient temperature 23° C/73.4° F
± 3° C/5.9° F. Specified at 115 V/230 V.
Cooling Time
CTC-660. . . . . . . . . 660 to 100°C / 1220 to 212°F. . . 39 minutes
CTC-660. . . . . . . . . . . .100 to 50°C / 212 to 122°F. . . 18 minutes
Time to Stability (typical)
CTC-660. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 minutes

 

Mains Power
Voltage. . . . . . . . . . . . . . . . . . . . . .115 V (90-127) / 230 V (180-254)
Max Power Consumption. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1150 VA
Frequency, US deliveries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Hz ±3
Frequency, non US deliveries. . . . . . . . . . . . . . . 50 Hz ±3, 60 Hz ±3

 

Physical Specifications
Dimension L x W x H. . .248x148x305 mm / 9.76×5.83×12.01 in
Weight
CTC-660. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6.1 kg / 13.4 lb
Immersion Depth
CTC-660. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115 mm / 4.53 in
Well diameter
CTC-660. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 mm / 1.02 in
Insert Dimensions (diameter x length)
CTC-660. . . . . . . . . . . . . . . . . . 25,7 mm x 120 mm / 1.01 x 4.72 in

 

Electrical
Switch Input (dry contact)
Test Voltage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Maximum 14 VDC
Test Current. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maximum 1 mA
Digital Interface
USB 2.0

 

Environmental
Operating Temperature
0 to 50°C / 32 to 122°F
Storage Temperature
-20 to 50°C / -4 to 122°F
Humidity
5 to 90% Rh, non-condensing
Protection Class
IP-10

 

External reference sensor
STS-120-A-966. . . . . . . . . . . . . . . . . . . . . . .0 to 660°C / 32 to 1220°F
Accuracy
Hysteresis (@ 0°C / 32°F) . . . . . . . . . . . . . . . . . . . . . . 0.01°C / 0.018°F
Long Term Stability (@ 0°C / 32°F). . . . . . . . . . . . 0.014°C / 0.025°F
Repeatability. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.004°C/ 0.007°F
Sensing element
Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pt100
Response time
STS-120-A: t0.5 (50%) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 sec.
STS-120-A: t0.9 (90%) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 sec.
Dimensions
Diameter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 mm / 0.157 in
Length. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151 mm / 5.95 in
Max. height over calibrator top. . . . . . . . . . . . . . . . .25 mm / 0.94 in

See more Dry Block/ Liquid here.

 

Reviews

There are no reviews yet.

Be the first to review “Ametek CTC-660 28 to 660°C (82 to 1220°F) Dry-Block Calibrator”

Your email address will not be published. Required fields are marked *


Rent the Ametek CTC-660 28 to 660°C (82 to 1220°F) Dry-Block Calibrator

Request Rental Quote Above

JM Test Rental options can help you save capital, get the latest technology, and expand your capabilities. Daily, Weekly and Monthly rates are available on select items.