Product Overview: Fluke Calibration 9100S Handheld Dry-Well Calibrator
The Fluke Calibration 9100S Handheld Dry-Well Calibrator sets a new standard in portable temperature calibration technology. Despite its remarkably compact size, this dry-well outperforms many larger units in its class, offering a perfect balance of portability and precision for field testing of RTDs, thermocouples, and small bimetal thermometers.
Ease of use is a hallmark of the 9100S. Its straightforward operation allows users to become proficient with the device in less than 15 minutes. The process is simple: plug it in, set the desired temperature, and insert the probe into the appropriately sized well. Users can then compare the device reading to the display temperature or an external reference to determine any errors.
At the heart of the 9100S is Fluke Calibration’s advanced temperature controller, which delivers impressive performance metrics. With 0.1°C resolution, ±0.5°C accuracy, and ±0.1°C stability, this dry-well provides the precision needed for critical temperature calibrations. The quick five-minute stabilization time further enhances efficiency, allowing technicians to complete more calibrations in less time.
The 9100S’s wide temperature range, reaching up to 375°C (707°F), makes it versatile enough to handle a broad spectrum of industrial temperature calibration needs. This combination of accuracy, speed, and range in such a compact package makes the Fluke Calibration 9100S Handheld Dry-Well Calibrator an essential tool for field technicians across various industries, setting a new benchmark for portable temperature calibration devices.
Specifications | 9100S | 9102S |
Range | 35°C to 375°C (95°F to 707°F) | –10°C to 122°C (14°F to 252°F) at 23°C ambient |
Accuracy | ±0.25°C at 50°C; ±0.25°C at 100°C; ±0.5°C at 375°C | ±0.25°C |
Stability | ±0.07°C at 50°C; ±0.1°C at 100°C; ±0.3°C at 375°C | ±0.05°C |
Well-to-well uniformity | ±0.2°C with sensors of similar size at equal depths within wells | |
Heating times | 35°C to 375°C: 9.5 minutes | Ambient to 100°C: 10 minutes |
Stabilization | 5 minutes | 7 minutes |
Cooling times | 375°C to 100°C: 14 minutes | Ambient to 0°C: 10 minutes |
Well depth | 102 mm (4 in); 1.6 mm (1/16 in) hole is 89 mm (3.5 in) deep | 102 mm (4 in) |
Removable inserts | N/A | Available in sizes from 1.6 mm (1/16 in) to 11.1 mm (7/16 in) [6.4 mm (1/4 in) and 4.8 mm (3/16 in) included] |
Power | 115 V AC (±10%), 55–65 Hz, 1.5 A or 230 V AC (±10%), 0.8 A, 45–55 Hz, 175 W | 94-234 V AC (±10%), 50/60 Hz, 60 W; or 12 V DC |
Size (H x W x D) | 57 x 125 x 150 mm (2.25 x 4.9 x 6.1 in) | 99 x 140 x 175 mm (3.9 x 5.5 x 6.9 in) |
Weight | 1 kg (2 lb 3 oz) | 1.8 kg (4 lb) |
Computer interface | RS-232 included | |
NIST-traceable calibration | Data at 50°C, 100°C, 150°C, 200°C, 250°C, 300°C and 375°C | Data at –10°C, 0°C, 25 °C, 50°C, 75 °C,100°C and 122°C |