Product Overview: Fluke 561 Infrared & Contact Thermometer
Fluke FLUKE-561 Infrared & Contact Thermometer
The Fluke 561 IR Contact Thermometer is a versatile tool designed for industrial, electrical, and HVAC/R professionals. It combines non-contact infrared temperature measurement with K-type thermocouple capability for contact measurements, making it fast, efficient, and easy to use.
The 561 allows you to quickly scan large areas or small objects without shutting down equipment, making it perfect for measuring hot, moving, electrically energized, or hard-to-reach items. Use it to check motors, insulation, breakers, radiant heating, pipes, corroded connections, wires, and ducts—without needing a ladder.
The included flexible pipe probe is ideal for taking superheat or internal temperature readings. You can also use any standard K-type mini connector thermocouple probe, ensuring compatibility with thermocouples you already own.
Additional Features:
- Hook-and-loop pipe probe for superheat, subcooling, and ambient measurements
- MIN, MAX, and DIF functions for quick problem identification
- Lightweight at only 12 oz (340g) and easy to operate.
General Specifications | |
Temperature | -40 to 550°C (-40 to 1022°F) |
Display resolution | 0.1°C (0.1°F) of reading |
D:S (distance to spot size) | 12:1 |
Easy emissivity selector | Adjustable with three settings: |
Low (0.3), medium (0.7). high (0.95) | |
Display accuracy [assumes ambient operating temperature of 23°C (73°F) to 25°C (77°F)] | ±1.0% of reading ±1% of reading or ±1°C (±2°F), whichever is greater below 0°C / 32°F, ±1°C (±2°F) ±0.1°/1° |
Response time | 500 mSec (95% of reading) |
Repeatability | ±0.5% of reading or ±1°C (±2°F), whichever is greater |
Spectral response | 8 µm to 14 µm |
Laser sighting | Single point laser |
Laser shutoff | Laser turns off above ambient temperature of 40°C (104°F) |
Laser power | Class 2(II) operation; Output < 1 mW, wavelength 630-670 nm |
Relative humidity | 10% to 90% RH non-condensing, at < 30°C (86°F) |
Power, battery life | 2 AA batteries (alkaline or NiCD) |
Battery life | 12 hours |
Display hold | 7 seconds |
Backlit display | Yes, LCD with dual temperatures (current and MAX/MIN/DIF/KTC), low battery, F/C indicator, and Scan/Hold options |
Warranty | 2 years |
Operating temperature | 0°C to 50°C (32°F to 120°F) |
Storage temperature | -20°C to 65°C (-25°F to 150°F) |
MAX, MIN, DIF temperatures | Yes |
Thermocouple Type K mini adapter input | Yes, compatible with industry standard K type probes with mini-connector. Displays to the thermometer temperature range. |
Thermocouple Type K fabric hook-and-loop fastener pipe probe | Yes, with a temperature range of 0°C to 100°C (32°F to 212°F) and accuracy of ±2.2°C (±4°F) |
HVAC measurement guide | Yes |