TEST EQUIPMENT
MADE EASY ™

Reconditioned Rosemount 1151 Pressure Transmitter

Rosemount Pressure Transmitter

Large selection of models available:

  • AP4, AP5, DP3, DP4, DP5,  DP6, DP7
  • DR2, GP0, GP9, DP8, HP5, HP6, HP7

 

QTY:
 

Product Overview: Reconditioned Rosemount 1151 Pressure Transmitter

 

Materials

  • Isolating Diaphragms: 316L SST, Hastelloy C, Monel, Tantalum Process Flanges
  • Adapters: Cadmium and Nickel plated CS, 316 SST, Hastelloy C, Tantalum

Features

  • Protocols available include 4-20mA HART, Analog, and Low Power
  • Differential, gauge and absolute pressure measurements
  • Pressure ranges up to 6000 psi

Accuracy

  • SMART: +/-0.1% of calibrated span
  • Analog: +/-0.2 to +/-0.25% of calibrated span

Transmitter Range Availability by Model (URL= Upper Range Limit)

 

Range code1151 Ranges (URL)DPHPGPDP/GP/SealsAPLT
330 inH2O (7.46 kPa)*N/A*N/AN/AN/A
4150 inH2O(37.3 kPa)******
55 750 inH2O (186.4 kPa)******
66 100 psi (689.5 kPa)******
77 300 psi (2,068 kPa)*****N/A
88 1,000 psi (6,895 kPa)*N/A*N/A*N/A
99 3,000 psi (20,684 kPa)N/AN/A*N/AN/AN/A
00 6,000 psi (41,369 kPa)N/AN/A*N/AN/AN/A

Rangeability

Output CodeMinimum Span(1) URL/50Maximum Span
S (DP and GP, SST, Range 3–8; HP SST, Range 4–7) S (All Others)URL/502x URL (2)
S (All Others)URL/ 50 (3)2x URL (2)
E, GURL/6URL
LURL/1.1URL
MURL/2URL

(1) Minimum span equals the upper range limit (URL) divided by rangedown.
Maximum Span

(2) Transmitter is capable of measuring from –URL to URL.

(3) Accuracy specification for calibrated spans from 1:1 to 6:1 of URL only.