JMTEST.COM • 800.353.3411 88 ELECTRICAL TEST • These High Current Test Sets are built for field or shop use. Designed using the latest technology; these units combine a variable high current output with the ap propriate controls and instrumentation. • The test set is ideal for testing thermal, magnetic, and solid-state motor overload relays as well as molded-case circuit breakers and ground fault trip devices. They can also be used in many other applications requiring a high current source. • The HC1 provides a short duration output of 1000 amps througha typical 150 ampere molded-case circuit breaker when an instantaneous trip element must be tested. • The HC2 is capable of a 2000 amp instantaneous output. Sufficient current is available for testing the time delay characteristics of motor overload relays and molded case circuit breakers. • The Phenix Models HC3 and HC5 Mobile High Current Test Sets are ideal for testing thermal, magnetic, and solid-state motor overload relays as well as molded-case circuit breakers and ground fault trip devices. The units are constructed with large pneumatic wheels for mobility in the roughest terrain. • Designed using the latest technology; these units combine a variable high current output with the appropriate controls and instrumentation. • The test sets have a maximum output current rating of 4000 and 5000 amps respectively and feature a digital ammeter and timer. The timer displays in both cycles or seconds modes. • They can also be used in many other applications requiring a high current source. Standard Accessories Include: Rugged carrying case, 2 (5ft.) timer control leads, 2 (5ft) low current leads, 2 (5ft) high current leads HC1 Dimensions: 21X17X13” Weight: 70 lbs HC2 Dimensions: 21x17x13” Weight 112 lbs Standard Accessories Include: Hard casing, 2 (8ft) timer control output leads, 4 (2ft) high current output leads, 2 (4ft) medium current output leads(4ga), 2 (6ft) low current output leads HC3 Dimensions: 23x23x46” Weight: 205 lbs HC5 Dimensions: 23x23x46” Weight 266 lbs HIGH CURRENT TEST SETS PHENIX HC1 & HC2 HIGH CURRENT TEST SETS PHENIX HC3 & HC5 HIGH CURRENT TEST SETS HIGH CURRENT TEST SETS POWER SPECIFICATIONS CHART HC1 HC2 Input 120 or 220 VAC, 50 or 60 Hz 120V 20 Amp Delay 20 Amp Delay 220V 10 Amp Delay 12 Amp Delay Output 0-120V@5A 0-70V@25A 0-24V@25A 0-14V@125A 0-6V@120A 0-7V@250A 0-3V@240A 0-3.5V@500A Overload 1000 Amps 2000 Amps POWER SPECIFICATIONS CHART HC3 HC5 Input 230 VAC 230 VAC 25 Amp Delay 50 Amp Delay Output 0-15V/0-200A 0-15V/0-333A 0-7.5/0-400A 0-10V/0-500A 0-3.75V/0-800A 0-5V/0-1000A Overload 3000 Amps 5000 Amps FOR ELECTRICAL SAFETY GLOVES SEE PAGE ?? Available for Rent CALL JM FOR PRICING CALL JM FOR PRICING **PRICES ARE SUBJECT TO CHANGE**
RkJQdWJsaXNoZXIy OTk3MQ==