JM Test Systems Product and Services Catalog Vol. IV 2024

JMTEST.COM • 800.353.3411 59 ELECTRICAL TEST HIPOTS (DC) PHENIX PAD10-25 10Kv AC 25kV DC HIPOT MEGOHMETER PHENIX PAD56 5Kv AC 6Kv DC HIPOT MEGOHMETER 15Kv DC HIPOT MEGOHMETER PHENIX PM15-2 HIPOTS (DC) AC AND DC TESTING CAPABILITY MODEL PAD10-25 AC/DC TESTING CAPABILITY 10 kV AC / 25 kV DC PAD56 AC/DC TESTING CAPABILITY 5 KV AC / 6 KV DC PM15-2 DC TESTING CAPABILITY 15 KV DC INSULATION RESISTANCE Values up to 150,000 MΩ At test voltages of 0.5 kV, 2.5 kV, 5 kV, 15 kV DC (a scale factor for other test voltages is provided) Values up to 1,000,000 MΩ At test voltages of 2.5 kV or 5 kV DC (a scale factor for other test voltages is provided) Values up to 3,000,000 MΩ At test voltages of 5 kV, 10 kV, 15 kV DC (a scale factor for other test voltages is provided) LEAKAGE CURRENT .02-5,000 microamps DC .1-10 milliamps AC .01-5,000 microamps DC .1-5 milliamps AC .01-2,000 microamps DC INPUT 120 VAC, 60 Hz, single phase, 1.2 Amps or 230 VAC, 50/60 Hz, single phase, .6 Amps 120 VAC, 60 Hz, single phase, .3 Amps or 230 VAC, 50/60 Hz, single phase, .15 Amps 120 VAC, 60 Hz, single phase, 1 Amps or 230 VAC, 50/60 Hz, single phase, .5 Amps OUTPUT ≈0-10 kV AC, 0-10 milliamps ≈0-25 kV DC, 0-5 milliamps Negative output, positive ground ≈0-5 kV AC, 0-5 milliamps ≈0-6 kV DC, 0-5 milliamps Negative output, positive ground ≈0-15 kV DC, 0-2 milliamps Negative output, positive ground METERING 4½” analog meter Accuracy: ±2% of full scale 3½” analog meter Accuracy: ±2% of full scale 3½” analog meter Accuracy: ±2% of full scale VOLT METER 3-ranges: 0-5/10/25 kV 2-ranges: 0-3/6 kV 2-ranges: 0-7.5/15 kV CURRENT METER 0-1/10 milliamps AC 0-10/100/1000/5000 microamps DC 0-5 milliamps AC 0-.5/5/50/500/5000 microamps DC 0-.5/5/50/500/5000 microamps DC RESISTANCE MΩ @ 500 V @ 2,500 V @ 2500 V @ 5,000 V @ 5,000 V @ 10,000 V .05-5 .25-25 .5-50 1-100 1-100 2-200 .5-50 2.5-250 5-500 10-1,000 10-1,000 20-2,000 5-500 25-2,500 50-5,000 100-10,000 100-10,000 200-20,000 50-5,000 250-25,000 500-50,000 1,000-100,000 1,000-100,000 2,000-200,000 5,000-500,000 10,000-1,000,000 10,000-1,000,000 20,000-2,000,000 @ 5,000 V @ 15,000 V @ 15,000 V .5-50 1.5-150 3-300 5-500 15-1,500 30-3,000 50-5,000 150-15,000 300-30,000 500-50,000 1,500-150,000 3,000-300,000 30,000-3,000,000 SAFETY & DESIGN FEATURES • Adjustable overcurrent trip point • Guarded measurement circuit • Multi-range current and voltage measurement • Zero start interlock • Surge and transient protection • Guard circuit for stray leakage current bypass • Direct megohm readings • Internal short circuit protection • Adjustable output current limit UNIQUE FEATURES • Internal discharge device • External interlock provision • Internal discharge device • Low ripple 0.4% peak-peak at full output • ISO17025 calibration upon request CABLES INCLUDED INPUT 10’ (3 m) Standard modular 3-wire cord mating to fused input module HIGH VOLTAGE OUTPUT 10’ (3 m) attached shielded cable with clip and insulator (removable on model PAD10-25) RETURN LEAD 10’ (3 m) red lead with insulated clip GROND LEAD 10’ (3 m) green lead with insulated clip PRICE Call for Pricing Call for Pricing Call for Pricing **PRICES ARE SUBJECT TO CHANGE**

RkJQdWJsaXNoZXIy OTk3MQ==